T-619 Universal Timer        TECHNICAL SALES BULLETIN

 

HOME

ABOUT ESD

PRODUCTS APP NOTES DOWN LOADS CONTACT ESD LIST PRICE

T-619

UNIVERSAL TIMER

LIFETIME WARRANTY

Features:

  • 2 Timing Ranges of 0-60 Seconds
    & 0-60 Minutes

  • Operates from 12 or 24VDC Automatically

  • Timer may be (Start) Triggered with
    a Positive/Negative/Normally Open/or Normally Closed Input

  • Start trigger may be Selected to Delay the Relay Pick Up or Delay
    the Relay Release

  • Flasher / Repeat Capability

  • LED Indicates Relay Energized

  • Sealed 6 Amp Form C Relay Contacts

 

  

 



DESCRIPTION
 

The T619 is a universal delay timer which may be selected to time intervals of 0-60 seconds or 0-60 minutes.  The timer may be selected to time from a positive or a common negative input.  By recycling the timer with a momentary input trigger, or timing a sustained input, the timer becomes very versatile as shown in the examples.  The timer may also be selected to be a versatile flasher.  The flasher is a square output when neither Delay Pick or Drop is selected.


 
SPECIFICATIONS
 

Operating Voltage ..................................... 10V - 29VDC

Operating Current @ 12VDC Relay De-energized ................  .5mA

Operating Current @ 12VDC Relay Energized ...................  30mA

DC Does not Have to be Filtered

Operating Temperature Range .........................  -50F to 150F

Relay Contacts (Sealed) ............................  15Amps @ 220V

Made in the USA

Double Stick Tape Pre-mounted and Mounting Holes

Small Size: ..................................  2.4”L x 2.7W” x 1”H

 

EXPLANATION OF TERMINALS

1) Start Trigger Input Terminal #1 Starts Timing with + or - Applied or Removed.

2) Power Input Terminals #2+ and #3- /12-24VDC

3) Form C RELAY Contacts Terminals #4, #5, & #6 with No Power Applied, are as Follows:  

           #4    Normally Open Contact

           #5    Swing Arm (Common)

           #6    Normally Closed Contact

 

EXPLANATION OF JUMPERS

INTRNL:     Internal (- or +) Selecting this applies either a positive or a negative voltage inside the timer to the Start terminal.  This feature provides more versatility to the timer.  Default is (-).

DELAY:      When PICK is selected, at start, the timer waits the adjusted time to energize the relay.  When DROP is selected the timer energizes at Start then waits the adjusted time to de-energize. Default is (PICK).

START:      Start timer with either a positive or a negative input.  Default is (+).

MIN / SEC:  This selects 0-60 seconds or 0-60 minutes.  Default is Seconds.

FLASH:      By selecting (Y)es the timer repeats itself until you remove the Start. When the default (N) is selected the timer does not repeat automatically.

 
 

 

 
pdf T619 Technical Sales Sheet/Instructions   T619 Diagram

Electronic Security Devices Incorporated 12/15/08 jdb

Specifications are subject to change without notice

 

 