SP-6 Series 12/24vdc 5A/3A Power Supplies/Charger SPS-6 12v/24v Supervised Power Supply/Charger module SP-6 12v/24v Power Supply/Charger module “E” adds PS-1485 9”x14” Enclosure “ACI” adds PDD-8ACI 8 input/output Access Control Relays with EOL Fire Interface “PCI” adds PDD-8PCI 8 output distribution with EOL Fire Interface module “FT” adds PDD-FT Fire Transfer Relay with EOL Interface SPS-6ED8 SPS-6E with 8 fused Class II Outputs SPS-6EC8 SPS-6E with 8 PTC Class II Outputs See comments regarding PTC’s on PDM Distribution Tech Sales All made with a Lifetime Warranty in the USA
Features SP-6 & SPS-6:
SPS-6B Supervised Features:
|
|
|---|
| DESCRIPTION | |
|---|---|
|
The SP & SPS-6B are heavy duty self contained, efficient, clean, off-line switching power supplies that are slide switch selectable between 12vdc at 5 Amps, and 24vdc at 3 Amps. Both have a precision lead acid battery(s) charger that obtains maximum battery life while providing a clean 12vdc or 24vdc uninterruptible power supply for access control security systems. The universal AC input allows these power supplies to be powered anywhere in the world without any alteration. The SP & SPS-6B have exceptional brown out capability with operation down to 60vac. The SP & SPS-6B have an extensive filtering system that provides a very clean output that can power most readers and sensitive equipment. Each is electronically protected against Battery(s) reversal, shorting or overloading. The DC outputs are all class II power limited, and thermally protected. Each of these protective features will self-restore. Before connecting load and battery(s), slide 12v/24v selector switch to desired voltage. Caution, damage can occur when switched with DC output load. Confirm proper voltage before connecting devices. The SPS-6B is UL Listed and has the additional supervisory features of a Battery disconnect relay that disconnects the battery(s) when they are depleted preventing deep discharge. Also there is a set of form “C” relay contacts that indicates AC power failure and another set of form “C” relay contacts to indicate low battery(s). Depending on load, low battery trouble Indicates about 70% battery capacity remaining. |
|
| SPECIFICATIONS | |
|
AC Input: L, N, G - 3P Terminal block Safety block with recessed hardware insulation that will accept up to 12AWG L= Line, N= Neutral, and G = Ground Optional 3 wire line cord P/N: ............................... HA-LC3SZIP AC Input Rating .................................. 90-250vac/150W/50-60Hz AC Input Operational ...................................... 60-264vac AC LED Indicator (Next to AC Input Terminal Strip) The AC indicator is a bi-color green and red led. This LED off with AC at the terminals would indicate a blown fuse link. A blown AC fuse link would indicate catastrophic failure and must be returned to the factory for repair. DC VOLTAGE SELECTOR SWITCH As marked on board, up is 24vdc and down is 12vdc. CAUTION To prevent damage, remove DC load and battery(s) connections before switching selector switch. DC OUTPUTS: 2P Terminal block Note: There is up to a 10 second delay for initial turn on on SPS-6 Output voltage Nominal ..................................... 12vdc/24vdc Output Voltage full operating range .............. 9.8–13.8vdc/19.6-28vdc Output continuous current 12v/24v ................................. 5A/3A AC Line regulation 85-264vac ................................... .03%Typ Output ripple & noise at full load ................. 180/50mv pp/rms Typ Current Overload Short Circuit Protection ........................... Yes Thermal runaway Protection .......................................... Yes Faults are auto restart Switching Frequency .............................................. 132KHz All Outputs are Class II Power limiting ............................. Yes DC LED Indicator (Adjacent to battery Header)....................... Red SPS-6 Supervised added features: AC Status Output Relay: 3P Terminal block AC Fail “C” contacts rating ................................... 2A/120vac Trouble Output: 3P Terminal block - annunciates low battery “C” contacts rating ....................................................... 2A/120vac AC Fail & Trouble are each have a three position terminal block marked “NO, C, NC” are shown in the Normal, energized, no fault condition. Trouble battery voltage (low)............................ 12.1vdc/24.2vdc Trouble LED Indicator ................................... On Green Normal Battery Cutoff SPS-6 Low Battery Cutoff Voltage ........................ 9.8vdc/19.6vdc Battery Cutoff Relay is normally energized for fail-safe operation. Battery Charging:............................ (Header plug marked [–Bat+]) Caution – To avoid spark, apply AC before connecting battery cable to battery. The battery charger is precision set to float charge 12V or 24V sealed or wet lead acid batteries. Two 12V batteries are connected in series for 24V. A 15” battery cable assembly is provided that plugs from module to battery. Red (+) 12vdc, Black (–) Neg. Optional 36” battery cable (1) P/N: .......................... WA-36IBAT Battery(s), any type of lead acid ......................... 12v 4AH-40AH UL evaluated ................................................. 7AH Battery(s) recharge ......................................... 400ma max Battery typical charge voltage 12V/24V ................ 13.65Vdc/27.30Vdc Battery(s) average recharging current rate ........................ 250ma Battery(s) PTC self resetting Circuit Breaker .................... 6A PTC Battery(s) Reverse hookup protection ................................ Yes To estimate the recharge time in hours for depleted battery(s), multiply the AH rating times 4 (AH x 4). As an example, a 24v system with two depleted 12v 7AH batteries would take about 28 hours to re-charge. See http://www.securitypower.com/an3batby.pdf for battery standby selection table. Environmental: Humidity .......................................... 95% RH Non Condensing Ts Storage Temperature .................................... -40oC – 85oC Ot Operating Temperature Range 100% rating: Ot Power module only ................................... -20 – 44oC Ot with E-89 Enclosure on wall ........................ -20 – 33oC each 3% load reduction increases Ot by ....................... +1oC Over temp shut down Mosfet Jt Temp ................................ 150oC Mechanical characteristics: SP/SPS-6B Module Dimensions ...................... 6.05”Lx3.87”Wx2.28”H Height includes 7/16” standoffs, not provided with module. Mounting Holes Center to Center ........................ 4.50”W x 3.41”H SPS-6B module only Weight ........................................ 12.4oz SPS-6E (SPS-6B in enclosure) ........................... 14” x 9” x 3.50” SPS-6E (with enclosure) Weight ................................. 6.85Lbs
Approvals: SP-6B & SP-6B meets safety ............................ UL1950 & EN60950 SPS-6 and all of its accessories are UL Listed US and C for Access Control & Burglar alarm systems UL294, UL603 & I:C5302 RoHs Lead Free |
|
|
|
Electronic Security Devices 2200 McArthur Dr. Tracy, CA 95376 |
E-mail: ESD@SecurityPower.com
|