| Rack Mount AC and
DC Models 8 or 16 outputs Access Control and CCTV |
|||||||||
|---|---|---|---|---|---|---|---|---|---|
|
|
| FEATURES | DESCRIPTION |
||||||
|---|---|---|---|---|---|---|---|
|
ESD rack mount power supplies are comprised
of an all aluminum case and UL506 24VAC transformer or 12vdc/24vdc off
line switching power supply coupled to one or two eight output power distribution
boards. The rack mount enclosure is 13” deep to put the terminals way back for easy access. The terminal block screws and wire entry are straight in horizontal and un-pluggable for faster installation and service. The rack mount front and back have a black anodized dress plate. The Dot above each output pair, indicates the neutral phase for AC and (com-) for DC. Each group of 8 outputs has a main power status LED along with a green status LED and fuse, replaceable from the front, for each output. Be sure total continuous current does not exceed the rating of the supply. All fuses, main and outputs are standard fast acting 5x20mm fuses. |
|
|
Rack Mount Selection Guide
RMD-16-12-24 Outputs 1-8 12Vdc at 6A Total - Outputs 9-16 24Vdc at
4A Total Input 10A Fuse 100-260Vac Specifications
General SpecificationAC input - see selection table - if selectable specify when ordering by default AC Models Output Voltage (full load 110vac input) ....................................................... 24VAC AC Models Typical Regulation from no load to full load ...................................................... 15% Output Current See Selection Table Overload Note: The AC models can handle a 200% current Overload for 2 minutes without the output voltage dropping below 20vac Operating Temperature range ............................................................................... -30o – 120oF Storage Temperature ......................................................................................... -50oF to 190oF Power Source Agency Approvals AC & DC models Dielectric Strength ........................................................... 2500VRMS Hi-pot DC models Dielectric Strength ....................................................................... 5200VRMS Hi-pot AC models Transformer Insulation .................... .................. Class B Insulation (266F) min. All AC transformers UL Recognized to UL 506 All AC Transformers CSA certified to C22.2 #66 DC Power sources SPS-20, SPS-5, SPS-5CE, SPS-10, SPS-10CD SPS-6.5, SPS-3.3 .................................................................................. are all Indicating LED’s 1 AC Main Power indicator for each group of 8 - shows main is on ................................... Green Output Status indicator - 1 for each output - indicates fuse and power good ....................... Green Mechanical Rack Mount Cabinet Size (2 rack high size) Brushed Aluminum ................ 19”W x 3.48”H x 13”D Front and Black covers are Black Anodized with white screened legend Weight RMA-1632, 24VAC at 32Amp (Heaviest Unit) ...................................................... 32lbs |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Specifications are subject to change without notice |
|
Electronic Security Devices 2200 North MacArthur Dr. Tracy, CA 95376 |
E-mail: ESD@SecurityPower.com
|